Brand Name : HiYi

Model Number : 9106

Certification : CE/ATEX

Place of Origin : China

MOQ : 1

Price : USD 150-- 300/set

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 10000 set/month

Delivery Time : 3-7 days

Packaging Details : color box

Name : HiYi CE/ATEX Approved LCD Display PID Sensor 14-24V RS485 Output Buzzer Alarm Fixed VOC Gas Detector

Gas : VOC(Volatile Organic Compounds)

Input Power : 9-24VDC

Display : Large LCD screen

Alarm : Sound+Light Alarm

Size : 14*10*4 cm

Weight : 2 Kg

Signal output : 4-20mA(two-wires), RS485

Contact Now

HiYi CE/ATEX Approved LCD Display PID Sensor 14-24V RS485 Output Buzzer Alarm Fixed VOC Gas Detector


Wall-Mounted Fixed Remote Gas Monitor System

OVERVIEW

9106 is a high performance intelligent toxic gas detection alarm which adopted Membrapor sensor from Switzerland, , high performance, supply couples of types of gas detection,low power microprocessor to ensure product performance and stability, real-time monitoring of the concentration of toxic gas.

Mainly used in petroleum chemical industry, metallurgy, mining, fire, gas, environmental protection, electric power, communication, paper making, printing and dyeing, food reserves, city water supply, sewage treatment, food, brewing, research, education, national defense and other places.

ABOUT VOC DETECTOR

Volatile organic compounds (VOC’s) are organic chemicals that have a high vapour pressure at ordinary room temperature. Their high vapour pressure results from a low boiling point, which causes large numbers of molecules to evaporate from the liquid or solid form of the compound and enter the surrounding air. This is why it is important to monitor for VOC using a range of voc gas detector.

In many types of industrial facilities, volatile organic compounds pose some of the greatest threats to the safety of employees. Commonly known as VOC, they can lead to workers suffering from nerve and kidney damage if left undetected. Because of this, companies within the oil and gas industry, as well as wastewater treatment plants, refineries, and processing facilities, have started using VOC gas detectors to protect employees as well as multi-million dollar buildings and equipment.

Buzzer Alarm VOC Fixed Gas Detector PID Sensor 14-24V RS485 Output

SPECIFICATION

Measured gas Toxic & Oxygen Gas Input power 12-24 VDC
Sensor Type Electro-chemical Current consumption 20-200MA
Sampling way Diffusion, pump (pipeline) Alarm error ≤ ± 10% alarm set value
Detection range Optional Work humidity 0-85%RH (no coagulation)
Accuracy Optional Preheating time 1 Min
Response time T90 ≤ 30S Signal output 4-20mA, RS485
Display LCD display real-time concentration, light emitting diode, buzzer alarm Equipment service life 10 years ( in the air )
Operating temperature -10 ℃ -40 ℃ Capacity 0.5A/125VAC or 1A/30VDC
Pressure range 860-1060hpa Repeat ≤±2%FS
Operating current 20-200mA Zero drift ≤±2%FS/6h
Span drift ≤± 5%FS/6h Dimension See size chart
Life for sensor See date of sensor Transmission distance 4~20mA≤100m ,RS485≤1000m
Housing color yellow Weight <2000g
Explosion-proof grade Exd II CT6 Cable ≥ RVVP9*0.3 mm2
Protection grade IP65 Electrical interface(thread) M26*P2.0 (explosion-proof connector: M26 M20)t
The power consumption ≤ 3W Material of housing Cast aluminum

FEATURES & BENEFITS
  • Three kind of signal output, RS485 and 4~20mA (three wire) digital / analog signal and switch at the same time.
  • Big screen segment type LCD real-time display gas concentration.
  • Gas concentration unit optional (such as ppm, mg/m3), it have the instrument status, fault and communication abnormality prompt function.
  • It can be set high and low alarm point, two level acousto-optic alarm.
  • Two relay to control peripheral devices (such as the action of machine and acousto-optic alarm).
  • Round casting stainless steel housing is suitable for offshore platforms, as well as high temperature, high humidity and other harsh environments.
  • Good sealing, anti-corrosion, explosion-proof and anti EMI, RFI function.
  • Suppoting use of our company ‘s GRI-9800 series alarm host.
  • European design standards.

Buzzer Alarm VOC Fixed Gas Detector PID Sensor 14-24V RS485 Output

APPLICATION

This fast-acting technology is ideal for difficult-to-protect applications such as:

  • production areas
  • tank farms and product storage
  • loading and unloading facilities
  • hazard waste treatment and storage
  • processes with high temperatures, pressure and flammable fuels
  • pump rows
  • manifolds
  • hot oil systems
  • rail car loading racks
  • hydrocarbon filling and storage areas
  • chemical storage tanks
  • aircraft hangars

Buzzer Alarm VOC Fixed Gas Detector PID Sensor 14-24V RS485 Output


Product Tags:

RS485 Fixed Gas Detector

      

VOC Fixed Gas Detector

      

VOC Gas Detector

      
China Buzzer Alarm VOC Fixed Gas Detector PID Sensor 14-24V RS485 Output wholesale

Buzzer Alarm VOC Fixed Gas Detector PID Sensor 14-24V RS485 Output Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing HiYi Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)